logo

AIOM

10-Input / 10-Output Module

The AIOM expander module supports 10 zone inputs and 10 outputs. It can be connected to the ATRIUM controller anywhere within a 1220 m (4,000 ft) range via the 4-conductor RS485 communication bus.
Effortless auto-detect technology identifies the AIOM on the communication bus and synchronizes it with the controller.

Scroll to learn more

Key features

  • 10 Inputs (20 using zone doubling)
  • 10 Outputs
  • Auto-detect technology (No jumpers or DIP switches)
  • 1220 m (4,000 ft) 4 conductor RS485 expansion bus
  • Comprehensive LED status indicators

Downloads & links

Features

  • Electrical specifications

    • Min. Voltage (V)
      12
    • Voltage AC/DC
      DC